找商網(wǎng)手機端:m.zhaosw.com
江蘇春晨電纜有限公司
主營產(chǎn)品: 電線電纜,電機引接線
萦萧萩营萦萬萪萬萤萦萧
YCB10KV扁電纜
價格
訂貨量(MI)
¥50.00
≥100
店鋪主推品 熱銷潛力款
聯(lián)系人 趙禮春
萦萧萩营萦萬萪萬萤萦萧
發(fā)貨地 江蘇省淮安市
在線客服
商品參數(shù)
|
商品介紹
|
聯(lián)系方式
品牌 春晨
顏色 黑
型號 YCB
截面 95
主要用途 扁電纜
產(chǎn)品名稱 高壓扁電纜
產(chǎn)品標準 CCC
產(chǎn)品規(guī)格 3*95
產(chǎn)品認證 CCC
光纜外徑 50
內(nèi)徑 20
商品介紹
江蘇春晨電纜有限公司生產(chǎn)YCB10KV扁電纜,(1)在建工程不得在外電架空線路正下方施工、搭設(shè)作業(yè)棚、建造生活設(shè)施或堆放構(gòu)件、架具、材料及其他雜物等。
(1) The construction in progress shall not be carried out directly under the overhead line of external power, the erection of operation shed, the construction of living facilities or the stacking of components, scaffolding, materials and other sundries.
(2)在建工程(含腳手架)的周邊與外電架空線路的邊線之間的最小安全操作距離應(yīng)符合表1規(guī)定。
(2) The minimum safe operation distance between the periphery of construction in progress (including scaffold) and the side line of external overhead lines shall comply with the provisions in Table 1.
表1 在建工程(含腳手架)YCB10KV扁電纜的周邊與架空線路的邊線之間最小安全操作距離
Table 1 minimum safe operation distance between the periphery of construction in progress (including scaffold) and the side line of overhead line
在建工程(含腳手架)的周邊與架空線路的邊線之間最小安全操作距離
The minimum safe operation distance between the periphery of construction in progress (including scaffold) and the side line of overhead line
注:上下腳手架的通道不宜設(shè)在有外電線路的一側(cè)。
Note: the passageway for up and down scaffold should not be set on the side with external power lines.
(3)施工現(xiàn)場的機動車道與外電架空線路交叉時,架空線路的最低點與路面的最小垂直距離應(yīng)符合表2規(guī)定。
(3) The minimum vertical distance between the lowest point of the overhead line and the road surface shall meet the requirements of Table 2 when the motorway on the construction site crosses with the external overhead line.
表2 施工現(xiàn)場的機動車道與架空線路交叉時的最小垂直距離
Table 2 the minimum vertical distance between the motorway and the overhead line at the construction site
施工現(xiàn)場的機動車道與架空線路交叉時的最小垂直距離
The minimum vertical distance between the motorway and the overhead line at the construction site
(4)起重機嚴禁越過無防護設(shè)施的外電架空線路作業(yè)。在外電架空線路附近吊裝時,起重機的任何部位或被吊物邊緣在最大偏斜時與架空線路邊線的最小安全距離應(yīng)符合表3規(guī)定。
(4) The crane is forbidden to cross the overhead line without protective facilities. When hoisting the overhead line or overhead line, the maximum distance between the overhead line and the overhead line should be in accordance with the provisions of the safety meter.
表3 起重機與架空線路邊線的最小安全距離
Table 3 minimum safety distance between crane and overhead line
起重機與架空線路邊線的最小安全距離
Minimum safety distance between crane and overhead line
(5)施工現(xiàn)場開挖溝槽邊緣與外電埋地電纜溝槽邊緣之間的距離不得小于0.5m。
(5) The distance between the edge of the trench excavated at the construction site and the edge of the trench for buried external power cables shall not be less than 0.5m.
(6)當達不到第(2)~(4)條中的規(guī)定時,必須采取絕緣隔離防護措施,并應(yīng)懸掛醒目的警告標志。
(6) When the requirements in (2) ~ (4) are not met, insulation and isolation protection measures must be taken, and eye-catching warning signs shall be hung.
(7)防護設(shè)施宜采用木,竹或其他絕緣材料搭設(shè),不宜采用鋼管等金屬材料搭設(shè)。防護設(shè)施應(yīng)堅固、穩(wěn)定,且對外電線路的隔離防護應(yīng)達到IP30級。
(7) The protective facilities should be built with wood, bamboo or other insulating materials, rather than steel pipes and other metal materials. The protection facilities should be solid and stable, and the isolation protection of external power lines should reach IP30 level.
(8)架設(shè)防護設(shè)施時,必須經(jīng)有關(guān)部門批準,采用線路暫時停電或其他可靠的安全技術(shù)措施并應(yīng)有電氣工程技術(shù)人員和專職安全人員監(jiān)護。
(8) When erecting protective facilities, approval must be obtained from relevant departments, temporary power failure of lines or other reliable safety technical measures shall be adopted, and electrical engineering technicians and full-time safety personnel shall be responsible for monitoring.
(9)防護設(shè)施與外電線路之間的安全距離不應(yīng)小于表4所列數(shù)值。
(9) The safety distance between protective facilities and external power lines shall not be less than the values listed in Table 4.
表4 防護設(shè)施與外電線路之間的最小安全距離
Table 4 minimum safety distance between protective facilities and external power lines
防護設(shè)施與外電線路之間的最小安全距離
Minimum safe distance between protective facilities and external power lines
(10)在外電架空線路附近開挖溝槽時,必須會同有關(guān)部門采取加固措施,防止外電架空線路電桿傾斜、懸倒
(10) When the trench is excavated near the overhead lines for external power supply, reinforcement measures must be taken together with relevant departments to prevent the poles from tilting and overhanging
聯(lián)系方式
公司名稱 江蘇春晨電纜有限公司
聯(lián)系賣家 趙禮春
手機 萦萧萩营萦萬萪萬萤萦萧
地址 江蘇省淮安市